Permit-Required Confined Spaces questions for the ASP

ASP11 Domain 2: Safety Programs and Concepts (2.8.i Confined spaces). 2 free questions below. Every answer quotes and links the regulation paragraph it rests on.

Regulations covered

Text pulled from the eCFR, current as of 2026-10-14.

Question 1

A plant plans to declassify a tank by relying on a portable blower that keeps the atmosphere within safe limits while employees work inside. The safety coordinator says that this counts as eliminating the atmospheric hazard, so the tank can be treated as a non-permit space under the declassification provisions. How should this be evaluated?

Show answer and source

Answer: D. Incorrect, because controlling atmospheric hazards through forced air ventilation does not constitute elimination of the hazards

The standard says that control of atmospheric hazards through forced air ventilation does not constitute elimination of the hazards. Entry relying on ventilation alone is handled under paragraph (c)(5), not by declassification. The 15-minute figure is not in the standard.

Answer D rests on

29 CFR 1910.146(c)(7)(ii)(opens ecfr.gov in a new tab)
“Control of atmospheric hazards through forced air ventilation does not constitute elimination of the hazards.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

Question 2

A plant's permit-required confined space (a process vessel) has a hazardous atmosphere that is controlled by continuous forced-air ventilation, plus an engulfment hazard from a product line that is blanked off. A supervisor proposes to declassify the vessel as a non-permit confined space by relying on the ventilation and the blank, and to record the basis in a signed, dated certification. Which response is correct under the standard?

Show answer and source

Answer: C. Declassification is not supported, because controlling atmospheric hazards with forced air ventilation does not count as eliminating them

Reclassification under (c)(7) requires that all hazards be eliminated, and the standard states that forced air ventilation controls atmospheric hazards but does not eliminate them. A certification cannot substitute for actual elimination, so the paperwork does not make declassification valid here.

Answer C rests on

29 CFR 1910.146(c)(7)(ii)(opens ecfr.gov in a new tab)
“Control of atmospheric hazards through forced air ventilation does not constitute elimination of the hazards.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

9 more permit-required confined spaces questions in the full ASP bank