CHST5 Domain 1: Hazard and Risk Identification and Control (K1.5 Fall protection, arrest and restraint). 3 free questions below. Every answer quotes and links the formula source it rests on.
A worker's harness D-ring is 5 ft above the walking surface. The worker uses a 6-ft lanyard attached to an anchorage level with the D-ring. Ignoring deceleration distance, what free fall distance results, and does the rigging meet OSHA's construction limit?
Show answer and source
Answer: D. 6 ft; meets the limit
Free fall is the lanyard length minus how far the anchorage is above the D-ring: 6 - (0) = 6 ft. A personal fall arrest system must be rigged so an employee cannot free fall more than 6 feet, so this meets the limit. Anchoring below the D-ring adds to free fall.
“be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;”
A worker's harness D-ring is 5 ft above the walking surface. The worker uses a 4-ft lanyard attached to an anchorage 2 ft above the D-ring. Ignoring deceleration distance, what free fall distance results, and does the rigging meet OSHA's construction limit?
Show answer and source
Answer: A. 2 ft; meets the limit
Free fall is the lanyard length minus how far the anchorage is above the D-ring: 4 - (2) = 2 ft. A personal fall arrest system must be rigged so an employee cannot free fall more than 6 feet, so this meets the limit. Anchoring below the D-ring adds to free fall.
“be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;”
A worker's harness D-ring is 5 ft above the walking surface. The worker uses a 6-ft lanyard attached to an anchorage 3 ft above the D-ring. Ignoring deceleration distance, what free fall distance results, and does the rigging meet OSHA's construction limit?
Show answer and source
Answer: B. 3 ft; meets the limit
Free fall is the lanyard length minus how far the anchorage is above the D-ring: 6 - (3) = 3 ft. A personal fall arrest system must be rigged so an employee cannot free fall more than 6 feet, so this meets the limit. Anchoring below the D-ring adds to free fall.
“be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;”