Skip to content

CHST Domain 1: Hazard and Risk Identification and Control

Domain 1 is 36.6% of the CHST, the heaviest of 4 domains by weight. PassCited has 276 questions for it.

BCSP's CHST5 Examination Blueprint, V.2022.04.12 weights Hazard and Risk Identification and Control at 36.6% of the CHST, a 4-hour exam. It is one of the two heaviest domains, so it deserves a large share of your study time.

Blueprint tasks we cover in this domain

Task numbers follow the BCSP blueprint. Tasks with no public-domain source (for example ISO standards or management theory) are thin or missing in our bank, and we say so rather than invent content.

  • K1.1 Hot work
  • K1.2 Electrical hazards and controls
  • K1.3 Excavations
  • K1.4 Working at heights
  • K1.5 Fall protection, arrest and restraint
  • K1.5 Fall protection, arrest, and restraint
  • K1.6 Confined spaces
  • K1.7 Struck-by
  • K1.8 Mechanized equipment
  • K1.9 Hoisting and rigging
  • K1.10 Crane operations
  • K1.11–K1.13 Material handling, storage, housekeeping
  • K1.14 Powder-actuated tools
  • K1.15 Hand and power tools
  • K1.16 Asbestos exposure
  • K1.17 Lead and heavy metals
  • K1.18 Noise
  • K1.18 Noise exposure
  • K1.19 Radiation
  • K1.20 Silica exposure
  • K1.21 Chemical exposure
  • K1.22 Environmental and weather conditions
  • K1.24 GHS
  • K1.28 PPE requirements, usage and limitations
  • K1.31 Concrete work
  • S1.1 Assess risk (severity x probability)
  • S1.5 Select protective equipment

Topics

Regulations this domain's questions cite most

Free Domain 1 practice questions

Question 1

A concrete crew is tying rebar mats on the face of a vertical wall form. The workers will be about 9 feet above the lower level. The competent person must select protection that complies with the standard. Which choice is compliant?

Show answer and source

Answer: B. Personal fall arrest systems, safety net systems, or positioning device systems

For employees on the face of formwork or reinforcing steel who could fall 6 feet or more, the standard lists personal fall arrest, safety net, or positioning device systems. Guardrails, warning lines, and controlled access zones are not the methods the standard lists for this work.

Answer B rests on

29 CFR 1926.501(b)(5)(opens ecfr.gov in a new tab)
“Each employee on the face of formwork or reinforcing steel shall be protected from falling 6 feet (1.8 m) or more to lower levels by personal fall arrest systems, safety net systems, or positioning device systems.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

Question 2

A crew sets up a 24-foot non-self-supporting extension ladder against a wall so the distance along the ladder between the foot and the top support is 20 feet. To meet the standard's angle requirement, approximately how far from the wall should the foot of the ladder be placed?

Show answer and source

Answer: A. 5 feet

The standard sets the horizontal distance at approximately one-quarter of the working length, which is 20 ft ÷ 4 = 5 ft. The 2.5-foot figure uses one-eighth, which applies only to wood job-made ladders with spliced side rails.

Answer A rests on

29 CFR 1926.1053(b)(5)(i)(opens ecfr.gov in a new tab)
“Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

Question 3

A crew is excavating a 6-foot-deep utility trench on a site that was previously a landfill. The competent person asks when the atmosphere in the trench must be tested. According to the standard, when is testing required?

Show answer and source

Answer: A. Before employees enter the excavation, because a hazardous atmosphere could reasonably be expected and the depth is greater than 4 feet

The standard requires testing before employees enter excavations deeper than 4 feet where a hazardous atmosphere could reasonably be expected, such as in landfill areas. Waiting for symptoms or using a 12-foot threshold would not protect workers, and neither appears in the standard.

Answer A rests on

29 CFR 1926.651(g)(1)(i)(opens ecfr.gov in a new tab)
“Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

See your Domain 1 score

The free 25-question CHST diagnostic is weighted like the blueprint and scores each domain, so you know where to spend your remaining days.

Other CHST domains

Domain names and weights from BCSP's public blueprint. Original practice questions, not real exam items. PassCited is not affiliated with or endorsed by BCSP.