Rescue and Emergency Services (Confined Space, Water, Falls) practice questions for the CHST exam
CHST5 Domain 2: Emergency Preparedness, Incident Investigation, and Response (K2.6 Response equipment; S2.1 Rescue planning). 3 free questions below. Every answer quotes and links the regulation paragraph it rests on.
- 29 CFR 1926.106: Working over or near water.
- 29 CFR 1926.1211: Rescue and emergency services. · how this section is tested
- 29 CFR 1926.502: Fall protection systems criteria and practices. · how this section is tested
- 29 CFR 1926.800: Underground construction.
Text pulled from the eCFR, current as of 2026-10-14.
A crew is cleaning a 12-foot-deep vertical storm vault classified as a permit-required confined space. The entry supervisor has chosen non-entry rescue. Each entrant wears a full body harness with a retrieval line attached at the center of the back. The lines are anchored to a fixed eye-bolt on the vault lid frame, and no mechanical retrieval device is on site because the supervisor says the lines are short enough to pull by hand. What is the correct determination?
Show answer and source
Answer: C. Non-compliant, because a mechanical device must be available to retrieve personnel from a vertical permit space deeper than 5 feet
The standard requires a mechanical device to be available for retrieving personnel from vertical permit spaces more than 5 feet deep. A fixed point alone is acceptable for shallower spaces, but not for this 12-foot vault. Wristlets are allowed only if a harness is infeasible or creates a greater hazard.
“A mechanical device must be available to retrieve personnel from vertical type permit spaces more than 5 feet (1.52 meters) deep.”
A crew is cleaning a vertical storage tank, a permit space 12 feet deep with a single top opening. The entry supervisor has selected non-entry rescue. Each entrant wears a full body harness with a retrieval line attached at the center of the back near shoulder level. The lines are anchored to a fixed eyebolt on the tank rim. No winch, hoist, or other mechanical retrieval device has been brought to the site. The tank's internal configuration is clear. What is the status of the retrieval system?
Show answer and source
Answer: B. Noncompliant, because a mechanical device must be available to retrieve personnel from vertical permit spaces more than 5 feet deep
The tank is a vertical permit space deeper than 5 feet, so a mechanical retrieval device must be available. A harness and a fixed anchor alone do not satisfy that requirement. Wristlets and anklets are only an exception when a harness is infeasible or creates a greater hazard.
“A mechanical device must be available to retrieve personnel from vertical type permit spaces more than 5 feet (1.52 meters) deep.”
A contractor is preparing for entry into a below-grade vault where the atmosphere may become IDLH. The safety technician is comparing two outside rescue services. Service A is fully equipped and proficient with the retrieval gear, but its crew would take well over half an hour to arrive from another county. Service B is equipped, proficient, and able to reach the vault in a few minutes. Based on the rule for selecting a rescue service, which action is correct?
Show answer and source
Answer: C. Select Service B, because the service selected must be able to reach victims within a time frame appropriate to the hazards of the space
The standard requires the selected service to have the capability to reach the victim within a time frame appropriate for the identified hazards, and an IDLH risk demands a fast response. Equipment proficiency alone does not make up for a slow response, and outside services are permitted if properly evaluated.
“Has the capability to reach the victim(s) within a time frame that is appropriate for the permit space hazard(s) identified;”