Skip to content

Air Contaminants and Silica (General Industry) questions for the CSP

CSP11 Domain 6: Occupational Health and Applied Science (6.1 Measurement, sampling and control of exposures). 2 free questions below. Every answer quotes and links the regulation paragraph it rests on.

Regulations covered

Text pulled from the eCFR, current as of 2026-10-14.

Question 1

An industrial hygienist is evaluating a worker's exposure to a single contaminant with an 8-hour TWA limit of 100 ppm. The worker spent 2 hours at 150 ppm, 2 hours at 75 ppm, and 4 hours at 50 ppm. Which conclusion is correct?

Show answer and source

Answer: D. The 8-hour TWA is 81.25 ppm, which is below 100 ppm, so the exposure is acceptable

The standard's formula weights each concentration by its duration: (2×150 + 2×75 + 4×50) ÷ 8 = 81.25 ppm, which is less than 100 ppm, so the exposure is acceptable. A short period above 100 ppm does not by itself make the TWA unacceptable.

Answer D rests on

29 CFR 1910.1000(d)(1)(ii)(opens ecfr.gov in a new tab)
“Substituting this information in the formula, we have (2 × 150 + 2 × 75 + 4 × 50) ÷ 8 = 81.25 ppm Since 81.25 ppm is less than 100 ppm, the 8-hour time weighted average limit, the exposure is acceptable.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

Question 2

A foundry uses the scheduled monitoring option for respirable crystalline silica. Initial personal sampling of a core-room operator showed an 8-hour TWA between the action level and the PEL. The employer repeated the sampling six months later, and the result was below the action level. Nothing about production, process, controls, personnel, or work practices has changed since. What must the employer do next for this operator's group?

Show answer and source

Answer: C. Repeat monitoring within six months of the most recent sample, and continue until two consecutive measurements taken 7 or more days apart are below the action level

The latest sample is a non-initial result below the action level, but only one such result exists, so the employer cannot yet stop. The standard requires repeat sampling within six months until two consecutive measurements, 7 or more days apart, are below the action level. Discontinuing now is wrong because that second qualifying measurement is missing.

Answer C rests on

29 CFR 1910.1053(d)(3)(v)(opens ecfr.gov in a new tab)
“Where the most recent (non-initial) exposure monitoring indicates that employee exposures are below the action level, the employer shall repeat such monitoring within six months of the most recent monitoring until two consecutive measurements, taken 7 or more days apart, are below the action level, at which time the employer may discontinue monitoring for those employees whose exposures are represented by such monitoring, except as otherwise provided in paragraph (d)(4) of this section.”

Report a problem

We re-check reported questions against the regulation and fix or remove them.

5 more air contaminants and silica (general industry) questions in the full CSP bank

The free 25-question diagnostic scores every CSP domain. The pass opens every question, timed practice, the AI tutor and full-length mocks.