Assigned protection factor (APF)

How much protection a class of respirator is expected to give inside a working respiratory protection program.

Definition, in the source's words

29 CFR 1910.134(b)(opens ecfr.gov in a new tab)
“Assigned protection factor (APF) means the workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer implements a continuing, effective respiratory protection program as specified by this section.”

What it means

APFs come from Table 1 in 1910.134(d)(3)(i)(A). A few to know: half mask air-purifying 10, full facepiece air-purifying 50, loose-fitting PAPR 25, pressure demand SCBA with a full facepiece 10,000.

An APF holds only inside a working program: fit testing, training, maintenance and medical evaluation.

Example

Air sampling shows 300 ppm of a vapor with a 50 ppm PEL. 300 ÷ 50 = 6 times the PEL, so the respirator needs an APF of at least 6. A half mask (APF 10) is enough on protection factor alone, if the cartridge suits the vapor.

Where it appears on the exam

Questions

What is the APF of a half mask respirator?
10, in Table 1 of 1910.134(d)(3)(i)(A).