29 CFR 1910.178: Powered industrial trucks
The official text is on the eCFR. This page maps how the section is organized, quotes the paragraphs our ASP, CSP practice questions are built on, and gives free questions you can try. Text below is quoted from the eCFR, current as of 2026-10-14; the section was last amended 2017-01-18.
How 29 CFR 1910.178 is organized
- (a) General requirements7 paragraphs
- (b) Designations13 paragraphs
- (c) Designated locations44 paragraphs
- (d) Converted industrial trucks1 paragraph
- (e) Safety guards2 paragraphs
- (f) Fuel handling and storage2 paragraphs
- (g) Changing and charging storage batteries12 paragraphs
- (h) Lighting for operating areas2 paragraphs
- (i) Control of noxious gases and fumes1 paragraph
- (j) Dockboards (bridge plates)1 paragraph
- (k) Trucks and railroad cars4 paragraphs
- (l) Operator training48 paragraphs
- (m) Truck operations15 paragraphs
- (n) Traveling18 paragraphs
- (o) Loading6 paragraphs
- (p) Operation of the truck5 paragraphs
- (q) Maintenance of industrial trucks13 paragraphs
- [Appendix A to § 1910.178]32 paragraphs
Paragraphs our practice questions cite most
Counted across the 20 live PassCited questions built on this section. This reflects our question bank, not the real exam.
“(7) The EX designated units are electrically powered units that differ from the E, ES, or EE units in that the electrical fittings and equipment are so designed, constructed and assembled that the units may be used in certain atmospheres containing flammable vapors or dusts.”
“(k) Trucks and railroad cars. (1) The brakes of highway trucks shall be set and wheel chocks placed under the rear wheels to prevent the trucks from rolling while they are boarded with powered industrial trucks.”
“(ii) Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.”
“(7) Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily.”
“(12) The atmosphere or location shall have been classified as to whether it is hazardous or nonhazardous prior to the consideration of industrial trucks being used therein and the type of industrial truck required shall be as provided in paragraph (d) of this section for such location.”
Free practice questions on 29 CFR 1910.178
Question 1
A safety coordinator is selecting a replacement electric lift truck for a solvent-blending room. Flammable vapors are present in the room's atmosphere. The facility's current electric trucks are an ES unit (extra safeguards against sparks and high surface temperatures) and an EE unit (motors and electrical equipment completely enclosed). Which designation is intended for use in this kind of atmosphere?
Show answer and source
Answer: B. EX
The standard describes EX units as the electric trucks whose electrical fittings and equipment are designed, constructed, and assembled for use in certain atmospheres containing flammable vapors or dusts. The EE and ES units only add safeguards over the basic E unit, such as spark prevention or enclosed motors, and are not described as built for flammable-vapor atmospheres.
Answer B rests on
29 CFR 1910.178(b)(7)(opens ecfr.gov in a new tab)“The EX designated units are electrically powered units that differ from the E, ES, or EE units in that the electrical fittings and equipment are so designed, constructed and assembled that the units may be used in certain atmospheres containing flammable vapors or dusts.”
Question 2
During a walk-through of a forklift charging area, a safety professional sees that an operator has parked an electric truck, set the brake, opened the battery compartment cover, and checked that the vent caps work before starting the charge. A contractor is using an angle grinder on a bracket on a workbench inside the same charging area. The grinder is throwing a steady stream of sparks. Which action does the standard require?
Show answer and source
Answer: B. Take precautions to prevent the sparks, such as stopping the grinding or moving it out of the charging area
The standard requires precautions to prevent open flames, sparks, or electric arcs in battery charging areas, so the grinding must be stopped or moved. A no-smoking rule does not cover sparks, which are a separate hazard. Closing the cover is wrong because the guidance calls for the cover to be open to dissipate heat.
Answer B rests on
29 CFR 1910.178(g)(11)(opens ecfr.gov in a new tab)“Precautions shall be taken to prevent open flames, sparks, or electric arcs in battery charging areas.”
Question 3
A lift truck operator has raised a loaded pallet to the height of the top rack tier. The truck is still in the aisle, and the pallet has not yet reached the rack opening. The pallet is stable with the mast tilted slightly back. To save time, the operator wants to tilt the mast forward now so the pallet will be ready to slide off when it reaches the rack. What should the operator do?
Show answer and source
Answer: C. Keep only enough backward tilt to stabilize the load, move forward until the pallet is in a deposit position over the rack, and tilt forward only then.
The standard prohibits tilting an elevated load forward until it is in a deposit position over a rack or stack, and it limits backward tilt to what is needed to stabilize the load. Being within rated capacity or moving slowly does not lift the prohibition, and tilting fully backward exceeds the "only enough" limit.
Answer C rests on
29 CFR 1910.178(o)(6)(opens ecfr.gov in a new tab)“An elevated load shall not be tilted forward except when the load is in a deposit position over a rack or stack. When stacking or tiering, only enough backward tilt to stabilize the load shall be used.”
Question 4
While preparing a new battery-changing area for electric lift trucks, a safety professional reviews the plan. It includes a designated charging room with an eyewash-style flushing station for spilled electrolyte, fire extinguishers, ventilation for gassing batteries, and wheel guards protecting the chargers from truck impact. Batteries would be removed from trucks by two workers who slide them onto a cart and then lift them onto the charging rack by hand. The plan also states that a carboy tilter will be used for electrolyte. Which gap in the plan does the standard require to be corrected?
Show answer and source
Answer: A. The plan must provide a conveyor, overhead hoist, or equivalent material handling equipment for handling batteries instead of hand lifting
The standard requires a conveyor, overhead hoist, or equivalent material handling equipment for handling batteries, so manual lifting by workers leaves a gap even though the other listed facilities are present. A carboy tilter is acceptable because the standard calls for a tilter or a siphon, and charging must be in a designated area, not wherever trucks park.
Answer A rests on
29 CFR 1910.178(g)(4)(opens ecfr.gov in a new tab)“A conveyor, overhead hoist, or equivalent material handling equipment shall be provided for handling batteries.”
Question 5
During an audit of a warehouse's battery charging area, a safety professional observes four electric lift trucks on charge. Which observation is a deficiency under the standard?
Show answer and source
Answer: B. A truck is being charged with its battery compartment cover latched shut while charging is in progress
The standard requires the battery or compartment cover to be open so heat dissipates, so a cover latched shut during charging is a deficiency. The other observations match the requirements to position the truck and apply the brake, keep vent caps functioning, prohibit smoking, and prevent open flames.
Answer B rests on
29 CFR 1910.178(g)(9)(opens ecfr.gov in a new tab)“Care shall be taken to assure that vent caps are functioning. The battery (or compartment) cover(s) shall be open to dissipate heat.”
Where it shows up in exam prep
Find out which regulations you'd miss
Other Part 1910 sections
- 29 CFR 1910.1020: Access to employee exposure and medical records
- 29 CFR 1910.1030: Bloodborne pathogens
- 29 CFR 1910.1053: Respirable crystalline silica
- 29 CFR 1910.106: Flammable liquids
- 29 CFR 1910.119: Process safety management of highly hazardous chemicals
- 29 CFR 1910.120: Hazardous waste operations and emergency response
This is a study aid, not legal advice or an official interpretation. Always check the current eCFR text. Original practice questions, not real exam items. PassCited is not affiliated with or endorsed by BCSP.